HUPLONG INDUSTRIES (M) SDN BHD
No 2-48, Jalan Perniagaan 2, Taman Pusat Perniagaan, Kampung Tengah Sungai Abong, 84000 Muar, Johor, Malaysia.
+606-9522968
24B, Jalan PSK 3,
Pusat Perdagangan Seri
Kembangan, 43300
Seri Kembangan,
Selangor, Malaysia.
+6016-3411889
NORRES PRO2AIR Pre-PUR 622
| Previous | 8 / 15 | Next |

- NORRES PRO2AIR Pre-PUR 622 Malaysia
- Membrane Tube Diffuser
- Wastewater Treatment Aeration Diffuser
- Fine Bubble Aeration Diffuser
- Pre-PUR Polyurethane Diffuser
Product details
- membrane tube diffusor, for industrial and municipal wastewater treatment plant, pressure diffusion with fine bubbles, oxygen input for nitrication in activation basins, permanent and intermittend ventilation
- oxygen input and circulation in xed-bed and bioreactors, thorough mixing of activation basins, sand trap louvre ventilation, renaturation of lakes and rivers, aquacultures, sh farming
PROPERTIES
- high energy savings when compared with comparative, market standard EPDM and silicone diffusors due to the much lower pressure loss
- extremely long lifetime and no curing due to the membrane not including a plasticizer
- very wide operating range: normal operation: 3-8, minimum 1, maximum 15 and purging operation 18 Nm³/(h*maer.)
- comparatively high oxygen input and oxygen transfer efficiency even with low density systems
- very fine and uniform bubble formation due to an optimized perforation
- easily and quickly fitted
- very good resistance to waste water and municipal sewerage in accordance with the latest instructions DWA-M 115
- microbe and hydrolysis resistant
- good resistance to oil, gasoline and chemicals
- conforms to RoHS guideline
TEMPERATURE RANGE
- -40°C to 90°C
DESIGN
- wall: special premium polyurethane (Pre-PUR®)
- wall thickness 0,7 mm approx.
DELIVERY VARIANTS
- further diameters and lengths available on request
- transparent (standard)
- special colours: full coloured
- customer-specific branding
HUPLONG INDUSTRIES (M) SDN BHD is the authorized distributor of NORRES industrial hoses in Malaysia.
HUPLONG INDUSTRIES (M) SDN BHD supplies genuine NORRES PRO₂AIR® Pre-PUR 622 membrane tube diffusers for industrial and municipal wastewater treatment applications. NORRES specifies this model for longer diffuser lengths and mounting without a support body.
NORRES PRO₂AIR® Pre-PUR 622 is a membrane tube diffuser for pressure diffusion with fine bubbles, oxygen input for nitrification in activation basins, and permanent or intermittent ventilation. Official applications also include oxygen input and circulation in fixed-bed and bioreactors, thorough mixing of activation basins, sand trap louvre ventilation, renaturation of lakes and rivers, aquaculture and fish farming.
The official diffuser wall is made from special premium polyurethane Pre-PUR® with an approximate wall thickness of 0.7 mm. NORRES specifies very good resistance to wastewater and municipal sewerage in accordance with DWA-M 115, together with microbe resistance, hydrolysis resistance and good resistance to oil, gasoline and chemicals.
NORRES states that PRO₂AIR® Pre-PUR 622 can reduce pressure loss compared with market-standard EPDM and silicone diffusers. The membrane does not contain a plasticizer, which NORRES states helps prevent curing over long operating periods. NORRES also specifies very fine and uniform bubble formation through optimized perforation.
The official operating range is 3 to 8 Nm³/(h*m aer.) under normal operation, with a minimum of 1 Nm³/(h*m aer.), a maximum of 15 Nm³/(h*m aer.) and a purging operation value of 18 Nm³/(h*m aer.). The official temperature range is from -40°C to +90°C.
Current standard variants have a size of 63 mm, an inside diameter of 64.5 mm and available lengths from 2 m to 50 m. Further diameters and lengths are available on request according to NORRES.
Our team can assist customers throughout Malaysia with NORRES hose selection based on hose diameter, conveyed material, operating temperature, airflow, vacuum condition, installation length and quantity requirement. For PRO₂AIR® Pre-PUR 622, selection should also consider aeration basin layout, diffuser length, required air flow, blower capacity, mounting method, wastewater condition and total diffuser quantity.
FAQ
Q: What is NORRES PRO₂AIR® Pre-PUR 622?
A: NORRES PRO₂AIR® Pre-PUR 622 is a membrane tube diffuser designed for longer diffuser lengths and mounting without a support body.
Q: What applications are officially listed for PRO₂AIR® Pre-PUR 622?
A: NORRES lists industrial and municipal wastewater treatment plants, pressure diffusion with fine bubbles, oxygen input for nitrification in activation basins, permanent and intermittent ventilation, fixed-bed and bioreactors, lake and river renaturation, aquaculture and fish farming.
Q: What is the official diffuser wall material?
A: The membrane wall is made from special premium polyurethane Pre-PUR® with an approximate wall thickness of 0.7 mm.
Q: What is the official air flow operating range?
A: NORRES specifies normal operation at 3 to 8 Nm³/(h*m aer.), with a minimum of 1 Nm³/(h*m aer.), a maximum of 15 Nm³/(h*m aer.) and purging operation at 18 Nm³/(h*m aer.).
Q: What is the operating temperature range?
A: NORRES specifies an operating temperature range from -40°C to +90°C.
Q: Does PRO₂AIR® Pre-PUR 622 help reduce pressure loss?
A: NORRES states that this diffuser can provide high energy savings compared with market-standard EPDM and silicone diffusers because of lower pressure loss.
Q: Is the diffuser resistant to wastewater and municipal sewerage?
A: NORRES specifies very good resistance to wastewater and municipal sewerage in accordance with DWA-M 115. It is also listed as microbe resistant and hydrolysis resistant.
Q: Which lengths are currently available?
A: NORRES currently lists standard lengths of 2 m, 5 m, 10 m, 20 m, 25 m, 30 m, 40 m and 50 m. Further diameters and lengths are available on request.
Q: How should the correct PRO₂AIR® Pre-PUR 622 diffuser be selected?
A: Selection should consider diffuser length, required operating air flow, basin geometry, blower capacity, installation method, wastewater condition, ventilation duty and total diffuser quantity.